M22 CK01 PDF

Moeller MCK01 single pole contact block with 1 normally closed contact and spring cage clamp terminals. This N. Up to 6 of the MCK01's can be added per operator along with MCK10 normally open contact blocks for complete functionality. The breadth of the RMQ-Titan line is impressive.

Author:Nikojinn Gozilkree
Country:Djibouti
Language:English (Spanish)
Genre:Business
Published (Last):9 October 2009
Pages:229
PDF File Size:1.10 Mb
ePub File Size:13.24 Mb
ISBN:364-1-52128-463-2
Downloads:5507
Price:Free* [*Free Regsitration Required]
Uploader:Gataur



NZM2: Only single contact can be fitted in left installation location of standard auxiliary contact. NZM4: Only single contact can be fitted in right installation location of standard auxiliary contact. NZM4, N S 4: approx. Overview Specifications Resources. Alternate Catalog No. EL-Nummer Norway. Delivery program Product range. Basic function accessories. Standard auxiliary contact, trip-indicating auxiliary switch. Construction size.

Connection technique. Degree of Protection. Connection to SmartWire-DT. For use with. Maximum travel [mm]. Minimum force for positive opening [ N].

Contact sequence. Contact travel diagram, stroke in connection with front element. Contact diagram. Connection type. Description of HIA trip-indicating auxiliary contact. Can be used with NZM1, 2, 3 circuit-breaker: a trip-indicating auxiliary contact can be clipped into the circuit-breaker. Can be used with NZM4 circuit-breaker: up to two standard auxiliary contacts can be clipped into the circuit-breaker.

Any combinations of the auxiliary contact types are possible. Description standard auxiliary contact HIN.

Switching with the main contacts Used for indicating and interlocking tasks. Can be used with NZM1 circuit-breaker: a standard auxiliary contact can be clipped into the circuit-breaker.

Can be used with NZM2 size circuit-breaker: a standard auxiliary contact can be clipped into the circuit-breaker. Can be used with NZM3, 4 circuit-breaker: up to three standard auxiliary contacts can be clipped into the circuit-breaker.

Marking on switch: HIN. NZM3: Only single contact can be fitted in installation locations of standard auxiliary contact. Technical data General. Lifespan, mechanical [Operations]. Actuating force. Climatic proofing. Ambient temperature Open. Mechanical shock resistance to IEC Shock duration 11 ms, half-sinusoidal.

Terminal capacities Solid. Terminal capacities Stranded. Terminal capacities Flexible with ferrule. Rated impulse withstand voltage [U imp ]. Rated insulation voltage [U i ]. Switching capacity. Auxiliary contacts. Rated operational voltage [U e ] Rated operational voltage [Ue]. Rated operational voltage [U e ] Rated operational voltage, max. Rated operational current [I e ] Different rated operational currents when used as auxiliary contact for NZM circuit-breaker.

Rated conditional short-circuit current [I q ]. Short-circuit protection max. Short-circuit protection Max. Operating times. Early-make time of the HIV compared to the main contacts during with make and break switching. Terminal capacities Solid or flexible conductor, with ferrule. Other technical data sheet catalogue. Maximum equipment and position of the internal accessories.

Rated operational current for specified heat dissipation [I n ]. Heat dissipation per pole, current-dependent [P vid ]. Equipment heat dissipation, current-dependent [P vid ].

Static heat dissipation, non-current-dependent [P vs ]. Heat dissipation capacity [P diss ]. Operating ambient temperature min. Operating ambient temperature max. Does not apply, since the entire switchgear needs to be evaluated. The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. Is the panel builder's responsibility. The specifications for the switchgear must be observed.

The device meets the requirements, provided the information in the instruction leaflet IL is observed. Technical data ETIM 7. Number of contacts as change-over contact. Number of contacts as normally open contact. Number of contacts as normally closed contact. Number of fault-signal switches. Rated operation current Ie at AC, V.

Type of electric connection. Mounting method. Lamp holder. Approvals Product Standards. UL File No. UL Category Control No. CSA File No. CSA Class No. North America Certification. CAD data. Product-specific CAD data.

Additional product information. Product photo. Declaration of Conformity. Flow diagramContact travel diagram. Wiring diagram. Flow diagram. Dimensions single product. Download-Center this item. Generate data sheet in PDF format. Generate data sheet in Excel format. Write a comment.